WT-206 "BWT 100 " BOILER SCALE & CORROSION INHIBITOR
Same formula as WT-208 below but without condensate line corrosion control amine. Formulated for applications where condensate treatment is prohibited, not required or where separate injection is preferred. May be used as a 2 drum treatment with WT-230.
COLOR: Dark Brown FRAGRANCE: Characteristic DOSAGE Varies pH: 13.0+ USDA: G6

55 gal container $10.50/gal, 35 gal pail $11.00/gal, 15 gal pail $11.50/gal, 5 gal pail $12.00/gal
Place Your Secured Order Below:

Qty: 

WT-2O8 "BWT-101 "BOILER & CONDENSATE LINE TREATMENT
Complete scale and corrosion control for steam boilers in a single package. Includes sulfite for oxygen pitting, polymers and phosphonates for scale inhibition and an amine for condensate line corrosion control. May be used with softened or high hardness make up waters. This high performance polymer formula protects systems operating with high make up rates. Higher dosage rates may be effectively employed for "on line" cleanups, with no attack on boiler metal.
COLOR: Dark Brown FRAGRANCE: Amine DOSAGE: Varies pH: 13.0+ USDA: G6

55 gal container $12.50/gal, 35 gal pail $13.00/gal, 15 gal pail $13.50/gal, 5 gal pail $14.00/gal
Place Your Secured Order Below:

Qty: 

WT-210 "BWT-102" OXYGEN SCAVENGER
Liquid blend of sulfite formulated to prevent oxygen pitting and general corrosion in boilers and industrial Systems. Used to boost sulfite residuals in systems being treated with WT-206 or WT-208;
COLOR: Brown FRAGRANCE: Characteristic DOSAGE: Varies pH: 12.0+ USDA: N/A

55 gal container $9.00/gal, 35 gal pail $9.50/gal, 15 gal pail $10.00/gal, 5 gal pail $10.50/gal
Place Your Secured Order Below:

Qty: 

WT-230 "CLT-100" CONDENSATE LINE CORROSION INHIBITOR
Dual neutralizing amine blend for condensate line corrosion control. Neutralizes carbonic acids which form in steam boiler condensate lines. Use with WT-206 or to boost WT-208 treatment levels.
COLOR: Straw/Amber FRAGRANCE: Ammoniacal DOSAGE: Varies pH: 12.0+ USDA: G6

Price 55 gal container $14.00/gal, 35 gal pail $14.50/gal, 15 gal pail $15.00/gal, 5 gal pail $15.50/gal
Place Your Secured Order Below:

Qty: 

WT-235 "RP-747" HOT OR CHILLED CLOSED LOOP TREATMENT
Closed loop corrosion and scale inhibitor. Used in chilled and hot loops, hot water boilers and radiators. Systems should be cleaned with WT-935 prior to treatment.
COLOR: Red FRAGRANCE: None DOSAGE: 1:200 pH: 12.0+ USDA: N/A

55 gal container $13.50/gal, 35 gal pail $14.00/gal, 15 gal pail $14.50/gal, 5 gal pail $15.00/gal
Place Your Secured Order Below:

Qty: 

WT-340 " CWT-5OO" COOLING TOWER CORROSION & SCALE INHIBITOR
An advanced liquid scale and corrosion inhibitor for use in open re-circulating cooling water systems. Maintains clean, scale, deposit and corrosion free surfaces which are required for system life and efficiency This is accomplished with one easy to use product. Provides effective scale and corrosion control in systems with corrosive make-up waters.
COLOR: Blue FRAGRANCE: Bland DOSAGE: 1.500 pH: 10 USDA: G7

55 gal container $11.00/gal, 35 gal pail $11.50/gal, 15 gal pail $12.00/gal, 5 gal pail $12.50/gal
Place Your Secured Order Below:

Qty: 

WT-350 " CWT-2000" COOLING TOWER CORROSION & SCALE INHIBITOR
An advanced liquid scale inhibitor for use in open re-circulating cooling water systems. Maintains clean, scale and deposit-free surfaces for system life and efficiency This is accomplished with one easy to use product. Provides effective scale control in systems with highly alkaline scaling makeup waters.
COLOR: Red FRAGRANCE: Bland DOSAGE: 1-2000 pH: 1-2 USDA:G7

55 gal container $14.00/gal, 35 gal pail $14.50/gal, 15 gal pail $15.00/gal, 5 gal pail $15.50/gal
Place Your Secured Order Below:

Qty: 

WT-360 " CWT-8000" CONCENTRATED
An advanced liquid scale and corrosion inhibitor for use in open re-circulating cooling water systems. Maintains clean scale and deposit-free surfaces for system life and efficiency Provides effective scale control in systems with highly alkaline scaling makeup waters.
COLOR: Colorless FRAGRANCE: None DOSAGE: 1-8000 pH: 1-2 USDA: G7

55 gal container $15.00/gal, 35 gal pail $16.00/gal, 15 gal pail $16.50/gal, 5 gal pail $17.00/gal
Place Your Secured Order Below:

Qty: 

System Descaler and Cleaner

WT-316 DESCALER#2
High activity blend of acids, corrosion inhibitors and synergistic wetting agents. Designed to effectively and economically remove scale deposits from heat exchange equipment surfaces. It contains a pH sensitive color indicator to help control de-scaling process.
COLOR:
Brown FRAGRANCE: Acid USE RATE: Varies pH: <1.0 USDA: A3
55 gal container $7.00/gal, 35 gal pail $7.50/gal, 15 gal pail $8.00/gal, 5 gal pail $8.50/gal, 4/1gal bottles $9.50/gal
Place Your Secured Order Below:

Qty: 

WT-317 ACID NEUTRALIZER
This product is a concentrated blend of alkali, and dispersing and passivating agents that provide economical neutralization of acidic cleaning solutions such as Amrep's "Misty Descaler#2".
COLOR:
Amber FRAGRANCE: None USE RATE: Varies pH: 13+ USDA: pending
55 gal container $7.00/gal, 35 gal pail $7.50/gal, 15 gal pail $8.00/gal, 5 gal pail $8.50/gal, 4/1gal bottles $9.50/gal
Place Your Secured Order Below:

Qty: 

WT-935 SYSTEM CLEANER
A concentrated triple application polymer product Prevents and removes accumulations of scale, corrosion, and organic matter in a wide range of open and closed re-circulating cooling and heating water systems. An excellent choice for "on line and new installation clean up jobs. Properly applied and controlled, it will dissolve or disperse a broad range of mineral and organic foulants. Formulated to provide corrosion protection to system metals. In old and heavily fouled Systems, deposits are removed slowly to prevent system plugging. For old and heavily fouled systems, clean up time can range from weeks for closed loop systems to several months for heavily scaled cooling towers. This product contains no acids or heavy metals.
COLOR:
Golden Straw FRAGRANCE: Bland DOSAGE: Varies pH: 13+ USDA: N/A

55 gal container $22.50/gal, 35 gal pail $23.00/gal, 15 gal pail $23.50/gal, 5 gal pail $24.00/gal
Place Your Secured Order Below:

Qty: 

Coil Cleaners

WT-412 COIL BRITE
A blend of high performance acid detergents designed for heavy duty cleaning and brightening of condenser cooling coils, fins and other equipment surfaces. High foaming cleaning action pushes dirt; lint, greases and oils out of coils. For good maintenance and equipment efficiency use two times per year. Use alkaline "Coil Cleaner II" periodically to remove grease and oily soils. This product is nonflammable, non-oily and effective in water with up to 500 ppm hardness. It is very effective on heavy oxidation and oily dirt; yet maintains its free rinsing qualities.
COLOR: Colorless FRAGRANCE: Glycol ether USE RATE: Varies pH: <l.0 USDA: pending

55 gal container $11.70/gal, 35 gal pail $12.20/gal, 20 gal pail $12.70/gal, 5 gal pail $13.20/gal, 4/1gal bottles $14.20/gal
Place Your Secured Order Below:

Qty: 

WT-417 COIL CLEANER II
A blend of high performance alkaline detergents and penetrants designed for heavy duty degreasing, cleaning of condenser and evaporator coils, fins and other equipment surfaces. For good maintenance and equipment efficiency, use monthly or as required to keep grease, oil, dust, lint, etc. off the unit Nonflammable, non-oily and effective in water with up to 500 ppm hardness. Very effective on heavy grease and oily dirt; yet maintains its free rinsing qualities. Condensate rinseable on evaporator coils. Surfactants in this product are biodegradable.
COLOR:
Yellow FRAGRANCE: Glycol ether USE RATE: Varies pH: 13.0 USDA: P1

55 gal container $8.50/gal, 35 gal pail $9.00/gal, 20 gal pail $9.50/gal, 5 gal pail $10.00/gal, 4/1gal bottles $11.00/gal Place Your Secured Order Below:

Qty: 

Defoamer

WT-4 18 "EDF-3" DEFOAMER
This product is a silicone anti-foam emulsion that will control foam in a wide variety of aqueous systems. Applications include industrial processes, cooling towers, boilers, waste streams and treatment facilities. EDF-3 is a non-hazardous organosilicone emulsion. It is highly effective in controlling foam in all types of process water systems created by a broad range of conditions.
COLOR:
Milk White FRAGRANCE: Bland DOSAGE: Varies pH: 7 U5DA: G7

55 gal container $14.30/gal, 35 gal pail $14.80/gal, 20 gal pail $15.30/gal, 5 gal pail $15.80/gal, 4/1gal bottles $16.40/gal
Place Your Secured Order Below:

Qty: 

WATER TREATMENT TESTING & CONTROL

Basic Boiler/Cooling Test Kit: AC-1392 $158.99 each

Quantity:

Complete Boiler/Cooling Test AC- l397 $365.00 each

Quantity:

Nitrite Test for RP-747: AC-1394 $45.00 each

Quantity:

Portable Battery Powered pH Meter: AC-1395 $70.00 each

Quantity:

Portable Battery Powered Conductivity Meter: AC- 1396 $80.00 each

Quantity:

Chemical Injection Pump: AC- 1420 $260.00 each

Quantity:

Tower Controller (ACT-1O2-C): AC-1410 $500.00 each

Quantity:

AmPump: AC-1426 $160.00

Quantity:

Cooling Water Problems
Cooling Tower-Heating Flow Schematic

Scaling: Water formed deposits result from naturally occurring minerals precipitating from water to form scale. The most common scales are calcium carbonate, calcium sulfate and silica or silicates. Scale buildup on surfaces can be extremely hard and difficult to remove. Scaling will drastically reduce heat transfer capacity and system energy efficiency

Corrosion: Cooling Systems are exposed to many types of corrosion, from general electrochemical corrosion, to pitting caused by deposits, electrolysis, or microorganisms. Corrosion can reduce the life-span of equipment by years, requiring expensive replacement. It can lead to costly equipment repairs and production downtime. Corrosion related deposits lead to reduced capacity and wasted energy because of heat transfer efficiency losses.

Fouling: Fouling occurs when solid materials form or contribute to the formation of deposit on equipment surfaces. They are introduced to the system as suspended solids and may enter by the makeup water, from corrosion by products, or as airborne materials. Examples include mud, sand, silt, clay oils, debris, organics, microbes, etc. These materials adhere to heat transfer surfaces and reduce heat transfer and water flow.

Microbiological Contamination: Microbial problems associated with industrial cooling water systems are caused by algae, fungi, and bacteria. They cause plugging, fouling, corrosion, and destruction of wooden cooling tower components. Many different bacteria species may exist in cooling water systems. Some of the problems caused include severe bacterial slimes and fouling, sulfuric acid, underdeposit corrosion and health hazards.

Boiler Water Problems
Boiler Water-Steam Flow Schematic

Scaling: As water is heated and converted into steam, contaminants brought into a boiler with makeup water are left behind. The boiler functions as a distillation unit, taking pure water out as steam, and leaving behind concentrated minerals and other contaminants in the boiler Scale forms as a result of the precipitation of normally soluble solids that become insoluble as temperature increases. Some examples of boiler scale are calcium carbonate, calcium sulfate, and calcium silicate.

Corrosion is a general term that indicates the conversion of a metal into a soluble compound. In the case of boiler metal, corrosion is the conversion of steel into rust In a boiler, two types of corrosion are prevalent: 1.) Oxygen pitting corrosion, seen on the tubes and in the pre-boiler section. 2.) Low pH corrosion, seen in the condensate return system. Corrosion of either type can lead to failure of critical parts of the boiler system, deposition of corrosion products in critical heat exchange areas, and overall efficiency loss.

Carryover is caused by either priming or foaming.

Priming is the sudden violent eruption of boiler water, which is carried along with steam out of the boiler, usually caused by mechanical conditions. Priming can cause deposits and around the main steam header valve in a short period of time.

Foaming causes carryover by forming a stable froth on the boiler water, which is then carded out with the steam. Over a period of time, deposits due to foaming can completely plug a steam or condensate line.

We accept All Major Credit Cards and Checks for our convenience.
We accept Purchase Orders via Phone, Fax or E-mail from approved agencies.

Global Environmental Services, Inc.
200 Main Street, Glen Gardner, NJ 08826
Phone: 888-668-9259 Fax 908-537-1114
Local Phone: 908-537-1115

E-Mail: The CEO, Dr. Arthur C. Groves III, PhD.



Like Music? Visit our Mirror Site at www.ges-inc.org.

Back to Top

| Home | Overview | Installation | RBC Products | Contact Us | Guest Book |
| Shopping Cart | Aerosol Lubricant | Aerosol Cleaners/Solvents | Antimicrobial |
| Bacteria/Enzymes | Boiler & Cooling Tower | Degreaser/Deodorizer | Flocculent |
| Fuel Oil Treatment | Lift Station Cleaners | Links | Oil Skimmers | Insect & Tick Repellent |
| Plow Blades | Kanaflex Suction Hose | Herbicide | Rodenticide |
| Storage Tank Rentals | Specialty Chemicals | Wasp and Hornet Killer | Asphalt Release Agent |
| Sun-Flow Hose | Hose Fittings |

Web Design by
Dr. Arthur C. Groves III, PhD.
Global Environmental Services, Inc.
Incorporated March 25,1997 in New Jersey

Copyright © 2000 GES, Inc. All rights reserved.

 

-->